“We are your most logical choice for human capital and asset protection services.”

Call Us: +1.888.293.2878

(24/7 Customer Service Line)

Mail us for help:

info@falkenworld.com

1808 Grandstand Dr.,

San Antonio TX 78238
Tel#+1.703.753.1158

SCIF Accreditation and Compliance

scif

Introducing Falken Industries, your comprehensive SCIF turnkey solution. With an impressive track record of over 20 years in the security industry, we are the clear and logical choice for all your “Sensitive Compartmented Information Facility” needs. Our expertise in providing top-notch cleared security services sets us apart from the competition.

At Falken Industries, we understand the critical importance of safeguarding sensitive information, and that’s why we offer a complete range of services to create and maintain SCIFs. From design and construction to installation of state-of-the-art security measures, our team is committed to delivering the highest level of quality and confidentiality.

By choosing Falken Industries as your SCIF partner, you gain access to our extensive network of experts who possess deep knowledge in secure facility design and implementation. Our team will work closely with you to tailor a solution that meets your specific requirements, ensuring that your sensitive information remains protected at all times.

But don’t just take our word for it – our satisfied clients are a testament to our excellence. We have successfully completed numerous projects across various industries, earning us a reputation for delivering exceptional results on time and within budget.

When it comes to your SCIF needs, trust Falken Industries to provide a turnkey solution that combines unrivaled expertise with unparalleled service. Contact us today and experience peace of mind knowing that your sensitive information is in safe hands.

The NSA methods for spying on computer emissions are classified, but some of the protection standards have been released by either the NSA or the Department of Defense. Protecting equipment from spying is done with distance, shielding, filtering, and masking. The TEMPEST standards mandate elements such as equipment distance from walls, amount of shielding in buildings and equipment, and distance separating wires carrying classified vs. unclassified materials, filters on cables, and even distance and shielding between wires or equipment and building pipes. Noise can also protect information by masking the actual data.

A SCIF, or Sensitive Compartmented Information Facility, is a government-accredited structure used exclusively for the storage, utilization, electronic processing, and discussion of classified information, research, and other data of a sensitive or Top Secret nature. These facilities may be permanent or temporary and have even been constructed to be airborne or seaworthy. The White House War Room is perhaps the most famous example of a SCIF.

The construction and installation of a SCIF must adhere to Intelligence Community Directive 705-01 Physical and Technical Security Standards for Sensitive Compartmented Information Facilities (ICD 705). This intricate set of standards outlines the specific security controls required to ensure the protection of the SCIF and all classified materials contained within. These controls include:Electrical: Telephones, security and emergency systems, and all other electrical power systems must be dedicated solely to the SCIF. TEMPEST countermeasures (Telecommunications Electronics Materials Protected from Emanating Spurious Transmissions) must prevent electric emanations generated within the SCIF from leaving the facility.

  • Acoustic: ICD 705 mandates a Sound Transmission Class of 45 or 50 to ensure all sounds within the SCIF are barely audible by human ears outside.
  • Visual: SCIFs are largely constructed without windows so that no one can see what is transpiring inside from any distance whatsoever.
  • Ductwork: All ductwork and ventilation units must include barred barriers to prevent intrusion. Inspection ports must also be installed. Breaks must also be outfitted with inserts ensuring that audio and/or electronic emanations do not travel beyond the SCIF.
  • Intrusion Detection Systems (IDS): Intrusion detection systems must be installed by a UL 2050-certified contractor, using UL 2050-approved components and central station monitoring by approved UL / DOD facilities.
  • Access Control: A minimum of a two factor authorization (Pin + Card) is required for access to prevent unauthorized entry, while all entrances and exits, along with accompanying security hinges, specialized exit alarms, sound seals and other components, must be built to vault-like specification.

    Our Brochures

    Capabilities Statement
    1.04mb
    Capabilities Brief
    1.04mb

    Best SCIF Services

    +1.888.293.2878

    Monday – Friday: 7:00 am -8:00 pm
    24/7 Emergency Service

    Visits: 83

    Subscribe to the Falken Newsletter!
    I have read the Privacy Policy and agree to its terms.